GDYM-1A Single Phase Electric Energy Meter Calibrator
GDYM-1A Single phase Electric Energy Meter Calibrator is multi-parameter measuring instrument which is full digital, mullti-function and high precision. It is not only enable to calibrating the error, but also to measure voltage, current effective value, active power, reactive power, apparent power, power frequency, power factor, phase relationship, etc. It is especially suitable for calibrating the measurement accuracy of Single-phase electric energy meter in the power supply unit.
Simple and quick operation, all operating procedures are displayed on the screen.
● To calibrate the electric energy meter of measuring system and measure the low voltage ratio.
● Using latest 32 bit 150MHz DPS core technology, 16 bit high precision converter, the error is more stable and accuracy is higher (this has qualitative difference with single-phase calibrator with meter chip).
● Large colorful LCD screen, displays calibrating setting parameters, harmonic, electrical parameters, error and all measuring data dynamically.
● Current clamp is used to simulate current generated by load, which simplified the field working and improved the work efficiency. The current of the terminal and the clamp as well as their power and power sum will be displayed at the same time.
● Using a 500A clamp and a small current clamp to measure the ratio of low voltage CT.
● Measure harmonic data from 2-43 times, current and voltage will real-time display each waveform, which helps to judge the on-site state.
● Calculating the constant of energy meter in one electric energy pulse period.
● Save data for 1000 meters.
● Connect with PC by RS232 series communication interface.
● With a low frequency pulse output, convenient for self-checking and inspection.
● The calibrator will alarm by sound and light when supplying 380V to voltage test line.
● When the simulation load current line is wrong connected to the neutral line of the meter, the first automatic protection will not output current. When making the fault connection again, the secondary protective fuse will be burn out, which applies absolutely protection. The calibrator will recover after replacing the fuse.
● The fuse will be burn out when the impulse line hit 220V, the calibrator will recover after replacing the fuse.
Measurement Range |
Accuracy |
||
Voltage |
10-300V |
±0.1% |
|
Simulation Current |
5A |
±20% |
|
Current Clamp |
100A, 500A |
±0.3%, ±0.5% |
|
Current Terminal |
0.05-10 A |
±0.1% |
|
Power |
Current Clamp |
100A, 500A |
±0.3%, ± 0.5% |
Terminal |
10A |
±0.1% |
|
Phase Angle |
-180--+180° |
±0.1° |
|
Frequency |
45-55Hz |
±0.01Hz |
|
Electric Energy |
100A Clamp(small) |
0.25A-110A |
±0.3%, ±0.5% |
500A Clamp |
25-1000A |
±0.5% |
|
Display Range |
100A Current Clamp: 0.01A-110A |
||
Terminal: 0.01A-10A |
|||
Electric Energy Pulse |
FL=1000 imp/kW.h |
||
Working Voltage |
AC 100 - 300 V |
||
Working Temperature |
-25℃~45℃ |
||
Working Humidity |
<95% No condensation |
||
Weight |
<1kg |
||
Volume |
215*105*70mm |
GDYM-1A Calibrator | 1 set |
100A clamp meter | 1 pieces |
Management Software (CD-ROM) | 1 piece |
Electronic meter pulse line | 1 piece |
Voltage cable | 1 piece |
Power cable | 1 piece |
232 communication line | 1 piece |
Photoelectric head | 1 piece |
0.5A Fuse | 1 piece |
Instrument case | 1 piece |
Manual | 1 copy |